Estaciones totales Cndadi
Estación total DTM622R4
Distance measurement |
||
Max distance (in good weather) |
Singles prism |
3.0Km |
Three prisms |
5.0Km |
|
No-prism |
400m |
|
Digital display |
Max:99999999.9999 m,Min.: 0.1mm |
|
Precision |
No-prism5+3ppm,have-prism 2+2ppm |
|
Unit |
m/ft for selection |
|
Time for measuring |
Single fine measurement 2 sec. tracking 0.8 sec |
|
Number of measurements |
1~ 99 |
|
Meteorologic correction |
Automatic correction of input parameter |
|
Atmospheric refraction and earth curvature correction |
Automatic correction of input parameter, K=0.14 |
|
Prism constant correction |
Automatic correction of input parameter |
|
Angle measurement |
||
Angle measurement method |
Absolute code |
|
Grating disc dia. (horizontal, vertical) |
79mm |
|
Min. reading displayed |
1″ |
|
Detection method |
Horizontal circle: 2 sides |
|
Precision |
2″ |
|
Telescope |
||
Imaging |
Right reading |
|
Barrel length |
170mm |
|
Objective lens ?effective aperture |
48mm |
|
Magnification |
30x |
|
Viewing angle |
1°30′ |
|
Resolution |
3.5″ |
|
Min. focus distance |
1.5m |
|
Automatic vertical compensator |
||
System |
Single axis, double axis liquid electronic sensor compensation |
|
Work range |
±3′ |
|
Precision |
±3 ″ |
|
Level |
||
Plate level |
20″/2mm, 30″/2mm |
|
Circular level |
8′/2mm |
|
Optical plummet |
||
Imaging |
Right reading |
|
Magnification |
3× |
|
Focusing range |
0.5m~∝ |
|
Viewing angle |
5° |
|
Display |
||
Type |
Two sides, graphically |
|
Data transmission |
||
Interface |
RS-232C |
|
Battery |
||
Power supply |
Rechargeable Ni-MH battery, rechargeable lithium battery |
|
Volt. |
Lithium battery: DC7.6V; Ni-MH battery: DC7.2V |
|
Continuous operation time |
8hours |
|
Size and weight |
||
Size |
174×207×383mm |
|
Weight |
6.8kg |
Estación total DTM624R

Telescope |
||||
Image |
Erect |
|||
Magnification |
30x |
|||
Effectiveaperture |
48mm |
|||
Resolving power |
3.75″ |
|||
Minimum focus |
1m |
|||
Stadia ratio |
100 |
|||
Sight distance precision |
≤0.4%D |
|||
Tube length |
165mm |
|||
Angle Measurement |
||||
Measuring method |
photoelectric detection by incremental encoder |
|||
Diameterof circle (vertical, horizontal) |
79mm |
|||
Minimum reading |
1″、5″、10″Selectable |
|||
Measuring unit |
360°/400gon/6400mil Selectable |
|||
Vertical angle0° |
Zenith0°/Horizontal0°Selectable |
|||
Accuracy |
2″ |
|||
Distance Measurement |
||||
Single prism(under fair weather condition) |
3km |
|||
Three prism(under fair weather condition) |
5km |
|||
Non-prism(under fair weather condition) |
400m |
|||
Display |
Max |
999999.999m |
Min |
1mm |
Unit |
m/ft Selectable |
|||
Accuracy |
±(3mm+2ppm·D) |
|||
Measuring time |
Fine single shot:?3S |
|||
Tracking:0.8S |
||||
Meteorological Correction |
Manual input, Auto correction |
|||
Reflection prism correction |
Manual input, Auto correction |
|||
Vial |
||||
Plate vial |
20″/2mm |
|||
Circular vial |
8′/2mm |
|||
Vertical Compensator |
||||
System |
Liquid-electric detection |
|||
Compensation range |
±3′ |
|||
Resolving power |
1″ |
|||
Optical Plummet |
||||
Image |
Erect |
|||
Magnification |
3× |
|||
Focusing range |
0.3m~∞ |
|||
Field of view |
5° |
|||
Display???? |
||||
Type |
LCD,Four lines,digital |
|||
Data Communication |
||||
Port |
RS-232C,USB |
|||
On-board Battery |
||||
Power resource |
Rechargeable Ni-H battery |
|||
Voltage |
DC7.2V |
|||
Continuous operation time |
BDC 3000mAh |
|||
Angle measurement: 20 hours |
||||
Distance measurement: 8 hours |
||||
Operation Environment |
||||
Operating temperature |
-20°~+45℃ |
|||
Size & weight |
||||
Dimension |
180mm×175mm×355mm |
|||
Weight |
6.5kg |
Estación total DTM626R
Distance measurement |
||
Max distance (in good weather) |
Singles prism |
3.0Km |
Three prisms |
5.0Km |
|
No-prism |
0.3~600m |
|
Digital display |
Max: 99999999.9999 m?Min.: 0.1 mm |
|
Precision |
No-prism5+3ppm, have-prism 2+2ppm |
|
Unit |
m/ft for selection |
|
Time for measuring |
Single fine measurement 2 sec. tracking 0.8 sec |
|
Number of measurements |
1~ 99 |
|
Meteorologic correction |
Automatic correction of input parameter |
|
Atmospheric refraction and earth curvature correction |
Automatic correction of input parameter, K=0.14 |
|
Prism constant correction |
Automatic correction of input parameter |
|
Angle measurement |
||
Angle measurement method |
Absolute code |
|
Grating disc dia. (horizontal, vertical) |
79mm |
|
Min. reading displayed |
1″ |
|
Detection method |
Horizontal circle: 2 sides |
|
Precision |
2″ |
|
Telescope |
||
Imaging |
Right reading |
|
Barrel length |
170mm |
|
Objective lens effective aperture |
48mm |
|
Magnification |
30x |
|
Viewing angle |
1°30′ |
|
Resolution |
3.5″ |
|
Min. focus distance |
1.5m |
|
Automatic vertical compensator |
||
System |
Single axis, double axis liquid electronic sensor compensation |
|
Work range |
±3′ |
|
Precision |
±3 ″ |
|
Level |
||
Plate level |
20″/2mm, 30″/2mm |
|
Circular level |
8′/2mm |
|
Optical plummet |
||
Imaging |
Right reading |
|
Magnification |
?3× |
|
Focusing range |
0.5m~∝ |
|
Viewing angle |
5° |
|
Display |
||
Type |
Two sides, graphically |
|
Data transmission |
||
Interface |
RS-232C |
|
Battery |
||
Power supply |
Rechargeable Ni-MH battery, rechargeable lithium battery |
|
Volt. |
Lithium battery: DC7.6V; Ni-MH battery: DC7.2V |
|
Continuous operation time |
8hours |
|
Size and weight |
||
Size |
174×207×383mm |
|
Weight |
6.8kg |
DTM952R
Wince total station DTM952R |
||
Distance measurement |
||
Maximum distance (under good weather conditions) |
Single prism |
3.0Km |
Three prisms |
5.0 Km |
|
Non-prism |
400m or 600m (optional) |
|
Numeric display |
Maximum: 99999999.999 m minimum: 1mm |
|
Accuracy |
Non-prism: 5+3ppm; prism: 3+2ppm |
|
Unit |
m/ft (optional) |
|
Measuring time |
Fine measurement: 2s each time; tracking: 0.8s |
|
Number of measurements |
1~99 measurements can be taken |
|
Meteorological correction |
It will automatically correct it with parameters entered |
|
Atmospheric refraction and earth curvature correction |
It will automatically correct it with parameters entered; K=0.14 |
|
Prism constant correction |
It will automatically correct it with parameters entered |
|
Angle measurement |
||
Measurement mode |
Absolute code |
|
Grating disc diameter (horizontal, vertical) |
79mm |
|
?Minimum display reading |
1″ |
|
Detection method |
Vertical disc: diameter |
|
Accuracy |
2″ |
|
Telescope |
||
Imaging |
Positive image |
|
Barrel length |
170mm |
|
Effective aperture of objective lens |
48mm |
|
Magnifying ratio |
30× |
|
Field angle |
1°30′ |
|
Resolution |
3.5″ |
|
Minimum focusing distance |
1.5m |
|
Automatic vertical compensator |
||
System |
Single- or double-axis liquid electronic sensing and compensation |
|
Operating range |
±3′ |
|
Accuracy |
±3 ″ |
|
Level |
||
Level tube |
20″/2mm, 30″/2mm |
|
Circular vial |
8′/2mm |
|
Optical plummet |
||
Imaging |
Positive image |
|
Magnifying ratio |
3× |
|
Focusing range |
0.5m~∝ |
|
Field angle |
5° |
|
Display |
||
Type |
Doublesides,lattice240X320?LCD,3.5inch touching screen operation |
|
Operation System |
Microsoft Windows CE.NET 5.0 |
|
Data transmission |
||
Interface |
RS-232C,USB,Bluetooth,SD-card |
|
Onboard battery |
||
Power |
Rechargeable mh-ni battery, rechargeable lithium battery |
|
\Voltage |
Lithium battery: DC7.6V; mh-ni battery: DC7.2V |
|
Continuous working hours |
4h |
|
Size and weight |
||
Overall dimensions |
174×207×383mm |
|
Weight |
6.8kg |